Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: https://dspace.mnau.edu.ua/jspui/handle/123456789/25322
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorМартиненко, Володимир Олександрович-
dc.contributor.authorMartynenko, Volodymyr-
dc.contributor.authorКошкін, Дмитро Леонідович-
dc.contributor.authorKoshkin, Dmitriy-
dc.contributor.authorСоколік, Віталій Дмитрович-
dc.contributor.authorSokolik, Vitaliy-
dc.contributor.authorСуковіцина, Ірина Миколаївна-
dc.contributor.authorSukovitsyna, Iryna-
dc.date.accessioned2026-05-08T10:16:11Z-
dc.date.available2026-05-08T10:16:11Z-
dc.date.issued2026-
dc.identifier.citationMartynenko, V., Koshkin, D., Sokolik, V., & Sukovitsyna, I. (2026). Intelligent system for automated design of energy-efficient facilities in the agro-industrial complex with built-in diagnostics of electrical machines. ITEGAM-JETIA, 12(58), 1475-1486. https://doi.org/10.5935/jetia.v12i58.3458uk_UA
dc.identifier.urihttps://dspace.mnau.edu.ua/jspui/handle/123456789/25322-
dc.description.abstractThe aim of the study was to substantiate the effectiveness of an intelligent system for automated design of energy-efficient facilities in the agro-industrial complex (AIC) with integrated diagnostics of electric drives. The methodology included experimental testing of asynchronous electric motors, numerical modelling, and optimization. Data analysis was performed using Student's t-test, analysis of variance, and principal component analysis. The results showed that in faulty electric motors, the current increased by 20%, the power factor decreased from 0.87 to 0.74, the vibration level exceeded that of serviceable samples by three times, and the temperature of the windings increased from 65 to 92 degrees Celsius. Numerical modelling showed a 9% reduction in energy consumption, a 17-degree Celsius decrease in temperature, a 16% increase in power factor, a 47% reduction in vibrations, and an increase in efficiency from 85 to 92%. Statistical analysis confirmed the reliability of the results, and the “serviceable/damaged” classification model achieved high accuracy with an area under the curve of 0.94. The scientific novelty lies in the first-ever combination of structural optimisation of electric drive parameters with built-in technical condition analysis in a single CAD/FEM environment.uk_UA
dc.language.isoenuk_UA
dc.subjectDiagnostic platformsuk_UA
dc.subjectOptimisation algorithmsuk_UA
dc.subjectPredictive maintenanceuk_UA
dc.subjectThermal stabilityuk_UA
dc.subjectVibration monitoringuk_UA
dc.titleIntelligent system for automated design of energy-efficient facilities in the agro-industrial complex with built-in diagnostics of electrical machinesuk_UA
dc.typeArticleuk_UA
Розташовується у зібраннях:Публікації науково-педагогічних працівників МНАУ у БД Scopus
Публікації у БД Scopus (Факультет менеджменту)
Публікації у БД Scopus (Інженерно-енергетичний факультет)

Файли цього матеріалу:
Файл Опис РозмірФормат 
3458-Article Text-10142-1-10-20260430.pdf887,83 kBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.